B&S2026 Figure 2 eigenvalue planning
<skill name="grill-me" location="[REDACTED_LOCAL_PATH]">
References are relative to [REDACTED_LOCAL_PATH]
Interview me relentlessly about every aspect of this plan until we reach a shared understanding. Walk down each branch of the design tree, resolving dependencies between decisions one-by-one. For each question, provide your recommended answer.
Ask the questions one at a time.
If a question can be answered by exploring the codebase, explore the codebase instead.
</skill>
Let's start a new episode. I would like to replicate Figure 2 in the paper which shows eigenvalues of the equilibrium solutions for one set of conditions (p = 300 hPa, T = 230 K, F = 1) for a range of vertical velocities (use the same range as for the Figure 1 replication). I would like to replicate these results using each of the three methods we're using (self-contained Python continuation code, AUTO and LOCA). Let's talk over what's needed and create some backlog issues to cover the work.
I checked the repo/source first. Important conflict:
- Existing Figure 1 reproductions use
w = 0.005–2.0 m s^-1. - The paper text for Figure 2 explicitly says
0.0005 ≤ w ≤ 2 m s^-1. - Figure 2’s low-velocity decade may matter because the paper says the “three real negative eigenvalues” regime occurs at higher temperature and very low vertical velocities.
Question 1: Should this new episode use the Figure 1 replication range you requested, 0.005–2.0, or the paper’s Figure 2 range, 0.0005–2.0?
My recommended answer: use the paper’s Figure 2 range 0.0005–2.0 as the primary reproduction target, and optionally include a comparison/metadata note that Figure 1 used 0.005–2.0. Otherwise we risk calling it a Figure 2 replication while excluding exactly the low-w regime Figure 2 discusses.
Yes, agreed, use the range from the paper.
Good — primary range: w = 0.0005–2.0 m s^-1.
Question 2: For the eigenvalues, should the episode target the eigenvalues of the paper’s physical ODE Jacobian J = ∂(dn/dt,dq/dt,ds/dt)/∂(n,q,s) at equilibrium, or the eigenvalues of our transformed log-coordinate equilibrium residual/Jacobian?
My recommended answer: use the physical ODE Jacobian. The paper’s Figure 2 and surrounding text refer to the Jacobi matrix of the linearized dynamical system and interpret stability/growth rates/oscillation frequencies from those eigenvalues. The log-coordinate residual Jacobian is useful for continuation, but its eigenvalues are not the same dynamical quantities and would make the reproduction scientifically misleading.
Exactly. We need to see the eigenvalues of the physical Jacobian.
Good.
Question 3: How should we compute the physical ODE Jacobian for Figure 2: derive/implement an analytic Jacobian, use automatic differentiation where available, or use finite differences of vector_field?
My recommended answer: make the Python analytic Jacobian the semantic reference, with tests against central differences. Then have AUTO/LOCA either:
- output/evaluate the same physical Jacobian/eigenvalues directly if practical, or
- at minimum output equilibria and compute physical eigenvalues in a shared post-processing step using the Python analytic Jacobian.
Reason: Figure 2 is about eigenvalues, so relying only on finite differences would add avoidable numerical ambiguity near Hopf sign changes. Analytic formulas are manageable here because vector_field is only three variables and, for the relevant equilibria, s > 1, so evaporation is inactive and the Heaviside branch is not problematic.
One of the main goals here is to see what AUTO and LOCA can actually do. Using the Python code to calculate the eigenvalues for the other approaches is a bit of a cheat. I know that AUTO may be awkward here, and I care less about that, but I would definitely like to see how easy it is to use AD within LOCA for this. The situation is a pretty common one: you mess around with your ODE system to make it nice for continuation, but need to calculate eigenvalues of the real Jacobian at the continuation points, so it would be good to see how LOCA handles this. For AUTO, I don't mind if you use the analytically calculated Jacobian in Python. When you compute the Python analytic Jacobian, use SymPy to do it, rather than doing the algebra "by hand".
That clarifies the backend-equivalence goal: eigenvalue computation itself is part of what we’re evaluating, not just an after-the-fact plot.
Current codebase fact: the LOCA C++ model already uses Sacado AD, but only for the log-coordinate continuation residual Jacobian:
loca/include/bergner_spichtinger_2026_loca/model.hpp
residual(log_state, log_w, env)returns[dn/dt / n, dq/dt / q, ds/dt]state_jacobian(...)differentiates that residual w.r.t.[log_n, log_q, s]
So Figure 2 needs a second AD path: evaluate the physical vector field [dn/dt, dq/dt, ds/dt] and differentiate w.r.t. physical [n, q, s].
Show remaining 3 lines
Question 4: For LOCA, should the task require the C++/Sacado physical Jacobian and eigenvalues to be produced by the LOCA-side executable as first-class output columns/artifacts, rather than only being used internally or checked in tests?
My recommended answer: yes. Add explicit LOCA-side output fields for the physical eigenvalues at each continuation point — e.g. sorted/paired lambda*_real, lambda*_imag, plus stability_class. Also keep the current continuation residual/Jacobian for solving. This makes the episode answer the real methodological question: “Can the transformed-continuation backend still report physical stability data without delegating to Python?”
Yes, exactly.
Good.
Question 5: How should we canonicalize/order the three eigenvalues across Python, AUTO, and LOCA so comparisons and plots are stable?
Paper convention:
λ3is “the real negative eigenvalue”λ1, λ2are either a complex-conjugate pair, or in the low-wregime all three are real and negative.
But numerically, eigenvalue ordering from numpy.linalg, LAPACK, Trilinos/Amesos/etc. is not guaranteed.
Show remaining 12 lines
My recommended answer: define a shared canonical ordering rule:
- If one conjugate pair exists:
lambda_pair: the two eigenvalues with largest absolute imaginary parts, ordered+imagthen-imag.lambda3: the remaining eigenvalue, expected real and negative.
- If all eigenvalues are effectively real:
- mark
eigenvalue_regime = "three_real"; - set
lambda3to the most negative / largest-magnitude negative real eigenvalue, because it corresponds to the fast contracting direction in the paper’s discussion; - set
lambda1,lambda2to the remaining two real negative eigenvalues ordered by real part.
- Use a shared tolerance like
abs(imag) <= 1e-10 * max(1, max_abs_lambda)for “real enough,” recorded in metadata.
This gives deterministic CSV columns and lets plots reproduce Figure 2 without backend-specific eigenvalue permutation noise.
Sounds good.
Question 6: Should this episode include reproducible digitization of the paper’s Figure 2 for quantitative comparison, or only reproduce the plot qualitatively/backend-to-backend?
My recommended answer: include source extraction/digitization as an explicit task, but treat it as secondary evidence.
Reason:
- Figure 2 is a plot of eigenvalues versus
w; a digitized paper overlay would help verify Hopf crossings nearw ≈ 0.048andw ≈ 0.77 m s^-1, the low-wthree-real regime, and scale/shape. - But eigenvalue curves may be visually hard to digitize accurately, especially if multiple branches overlap and if axes use log scaling.
- Therefore the primary acceptance target should be backend agreement plus paper-described qualitative landmarks; digitized Figure 2 residuals can be a curated QA artifact with documented uncertainty, similar to Figure 1.
Agreed. Digitization would be nice, but the imaginary parts in particular may be hard to extract cleanly.
Question 7: Should Figure 2 be one integrated new episode covering Python + AUTO + LOCA together, or three separate backend episodes like Figure 1 used (002 Python, 003 AUTO, 004 LOCA)?
My recommended answer: make this one integrated episode, probably episodes/005-figure2-eigenvalues/, with tasks split by backend.
Reason:
- Figure 2 is not a large branch-family build-out like Figure 1; it is one parameter slice:
p=300 hPa,T=230 K,F=1,w=0.0005–2. - The central scientific object is backend comparison of physical eigenvalue reporting, so separating by backend would scatter the methodological comparison.
- We can still create backlog issues in phases:
- episode scaffold + source/digitization plan,
- Python physical Jacobian/eigenvalue reference,
Show remaining 3 lines
- AUTO Figure 2 branch/eigenvalue workflow,
- LOCA Sacado physical Jacobian/eigenvalue workflow,
- backend/paper comparison plot and summary.
Yes, one episode, multiple tasks.
Question 8: For AUTO, what level of “native backend eigenvalue support” should we require?
Options:
- Minimal/acceptable: use AUTO only to compute continuation equilibria, then compute physical eigenvalues in Python using the SymPy-derived analytic Jacobian.
- Intermediate: investigate whether AUTO can expose/record stability/eigenvalue data for this equilibrium continuation, document the attempt, but fall back to Python analytic eigenvalues if awkward.
- Strict: require AUTO-side eigenvalue calculation/output before the task can be called done.
My recommended answer: choose option 2. Make “investigate/document AUTO-native stability support” part of the AUTO task, but allow Python analytic Jacobian fallback for curated outputs. AUTO is less central to the methodological question here, and forcing strict AUTO-native eigenvalues could burn time on tooling rather than science. LOCA should be the strict native/AD eigenvalue backend.
Yes, option 2. My experience with AUTO is that this sort of thing can be awkward and you end up writing extra tools outside AUTO to do it. If it turns out to be painful, it's OK to fall back on the Python eigenvalue calculator.
Question 9: What should count as the “core reproduced Figure 2” artifact: a paper-style plot only, or a richer backend comparison package?
My recommended answer: require a richer package, with the paper-style plot as the headline artifact:
outputs/figure2_eigenvalues/figure2_reproduction.png- top panel: real parts vs
w - bottom panel: imaginary parts vs
w - log-scaled
waxis over0.0005–2 - backend curves/markers distinguish Python, AUTO, LOCA
- optional digitized paper markers if feasible
Show remaining 15 lines
- backend-normalized CSVs:
- one branch/eigenvalue CSV per backend
- combined comparison CSV
- summary JSON/CSV:
- Hopf crossing estimates,
three_realinterval,- max Python-vs-AUTO and Python-vs-LOCA eigenvalue differences,
- LOCA physical-Jacobian provenance: Sacado AD, not Python post-processing.
- metadata:
- sorting tolerance,
- Jacobian method per backend,
- continuation/eigenvalue commands,
- source/digitization uncertainty notes.
This keeps the visual reproduction useful but makes the backend-method comparison auditable.
That's good.
Question 10: For the equilibrium branch points used for eigenvalues, should each backend generate its own continuation over w = 0.0005–2, or should some backends reuse/interpolate another backend’s branch points?
My recommended answer: each backend should generate its own branch/equilibrium sequence over the full Figure 2 range, but comparisons should interpolate onto a shared/reference grid afterward.
Reason:
- The point is partly to see what each method can do.
- Python can generate a dense log-
wgrid directly. - AUTO and LOCA should each demonstrate they can continue the transformed equilibrium system over the extended low-
wrange. - For comparison, use Python’s dense log-
wgrid or a fixed canonical grid, then interpolate backend eigenvalues carefully. But raw backend outputs should remain independently generated and archived.
Agreed.
Question 11: What aerosol number concentration N_a should Figure 2 use?
Known repo context:
- Figure 1 reproduction inferred
N_a = 1.0e10 m^-3(10000 cm^-3) because the Figure 1 caption omitted it but the plotted saturation ratios matched Appendix A2’s “unrealistically high aerosol” reference value. - Figure 2 text/caption gives
p = 300 hPa, T = 230 K, F = 1, but likewise does not explicitly mentionN_a.
My recommended answer: use the same inferred Figure 1/Appendix A2 value, N_a = 1.0e10 m^-3, and document it as an assumption inherited from the Figure 1 reproduction notes unless source inspection reveals a Figure 2-specific value. This keeps the equilibrium branch consistent with the existing reproduced model configuration and avoids introducing a hidden parameter change.
I think that's right: it's the "unrealistically high" value.
Question 12: Should the SymPy-derived physical Jacobian be generated once into a reusable Python module, or should scripts call SymPy at runtime?
My recommended answer: generate/maintain it as reusable package code in src/bergner_spichtinger_2026/, with tests proving it matches finite differences and the source expression.
Concretely:
- add something like
src/bergner_spichtinger_2026/jacobian.py; - include a SymPy construction function or generation script so provenance is explicit;
- expose
physical_jacobian(n, q, s, env)andphysical_eigenvalues(state, env); - tests compare against central finite differences of
vector_field.
Show remaining 1 line
I would avoid making every Figure 2 run depend on live SymPy simplification. SymPy should be the derivation/provenance tool; NumPy should evaluate the generated expressions during reproduction.
Agreed.
Question 13: For LOCA/C++, how should we compute the eigenvalues once Sacado has produced the physical 3×3 Jacobian?
Options:
- Use a small dedicated C++ eigenvalue library/function for real
3×3matrices. - Use LAPACK directly, e.g.
dgeev, since LOCA/Trilinos builds already depend on dense linear algebra. - Output the Sacado physical Jacobian from C++ and compute eigenvalues in a separate non-Python tool.
My recommended answer: use LAPACK dgeev from the LOCA-side executable if already available in the build. It is standard, robust, and keeps eigenvalue computation backend-side. Also output the physical Jacobian columns optionally or in a separate raw artifact so Python tests can verify LOCA’s Jacobian/eigenvalues without owning the production calculation.
Does Trilinos not have a built-in package for this sort of thing? Or are its own eigenvalue solvers only for large systems?
Yes: Trilinos has relevant pieces, but for this 3×3 dense nonsymmetric Jacobian, the practical Trilinos-native route is usually a LAPACK wrapper, not a large-scale eigensolver.
- Anasazi is Trilinos’ eigensolver package, but it’s aimed at large-scale iterative eigenproblems, typically sparse/distributed operators. Using it for a dense
3×3matrix would be absurd overhead. - Teuchos::LAPACK / Trilinos LAPACK wrappers are the likely right fit if enabled in this Trilinos build. They wrap routines like
GEEVfor nonsymmetric dense eigenvalues. - Direct LAPACK
dgeevis the fallback if the Teuchos wrapper is unavailable or awkward.
So I’d revise my recommendation:
Recommended answer: first try Teuchos::LAPACK<int, double>::GEEV inside the LOCA-side executable. If that’s not available in the installed Trilinos, fall back to direct LAPACK dgeev. Avoid Anasazi for this task.
Show remaining 1 line
The backlog task should explicitly include: “investigate and use Trilinos/Teuchos dense LAPACK eigenvalue support if available; document fallback.”
Sounds good. I think the Trilinos installation should have Teuchos.
Question 14: For LOCA output, should we include both the physical Jacobian matrix entries and eigenvalues in the normalized CSV, or keep Jacobian entries in a separate diagnostic/raw file?
My recommended answer: include eigenvalues and classification in the normalized branch CSV, and put full physical Jacobian entries in a separate raw/diagnostic CSV or optional columns.
Reason:
- Normalized branch rows should stay readable and focused:
w, equilibrium state, residual norm, convergence, physical eigenvalues, stability/regime. - The full
3×3Jacobian is valuable for tests/debugging/provenance but clutters the primary comparison table. - For LOCA specifically, raw diagnostics should prove the eigenvalues came from the C++/Sacado physical Jacobian path, not Python post-processing.
Agreed.
Question 15: Should Hopf crossing locations be computed as part of this episode, or only inferred visually from sign changes in the plotted real parts?
My recommended answer: compute them explicitly for each backend and include them in the summary.
Acceptance target:
- detect sign changes of
Re(lambda_pair)overlog_w; - refine crossing estimates by interpolation or a scalar root solve where practical;
- compare against paper text landmarks: approximately
w ≈ 0.048andw ≈ 0.77 m s^-1; - report backend-to-backend differences in the two Hopf locations.
Show remaining 1 line
This makes the Figure 2 reproduction more than a plot: it verifies the stability transitions the paper discusses.
Yes. In the next episode we're going to look at the Hopf points more carefully, so this is a good warm-up.
Question 16: Should this episode stop at “detect Hopf crossings from eigenvalue sign changes,” or should it also ask AUTO/LOCA to perform formal bifurcation/Hopf detection?
My recommended answer: stop at eigenvalue-derived crossing detection for this episode, and create a later episode/task for formal Hopf continuation.
Reason:
- Figure 2 itself is eigenvalues along equilibrium solutions, not a formal Hopf-point continuation study.
- You already said the next episode will examine Hopf points more carefully.
- For this episode, formal AUTO/LOCA bifurcation detection would expand scope and risk distracting from the main goal: physical Jacobian/eigenvalue reporting across transformed-continuation workflows.
Yes. Just do a simple zero-crossing detection for this episode.
Question 17: What grid density/continuation sampling should we require over w = 0.0005–2?
My recommended answer: use a dense canonical log-spaced comparison grid, e.g. 400–600 points, and allow each backend’s raw continuation grid to differ.
Why:
- Figure 2 needs smooth real/imaginary curves on a log-
waxis. - Simple zero-crossing estimates improve with dense sampling near the two Hopf transitions.
0.0005–2spans [REDACTED_LOCAL_PATH] decades, so 500 log-spaced points is still cheap for a 3-variable equilibrium problem.- Raw backend outputs can be their natural continuation points; comparison/plotting can interpolate onto the canonical grid and/or ask scripts to sample densely enough.
Show remaining 1 line
I’d set acceptance criteria as: at least 400 finite, converged points per backend across the full range, unless a backend documents a justified lower raw count plus interpolation/refinement around crossings.
Agreed.
Question 18: Should this episode treat the existing Figure 1 backend comparison utilities as reusable infrastructure to extend, or create Figure 2-specific comparison code from scratch?
My recommended answer: extend/reuse the pattern, but probably not the exact Figure 1 module wholesale.
Concretely:
- keep shared, generic pieces in
src/bergner_spichtinger_2026/, such as: - interpolation over
log_w, - relative/absolute difference summaries,
- metadata writing helpers if already cleanly reusable;
- create a Figure 2-specific module/script for:
Show remaining 6 lines
- eigenvalue canonicalization,
- stability classification,
- Hopf zero-crossing detection,
- real/imaginary panel plotting.
This avoids over-generalizing the Figure 1 comparison module, which is currently variable/value oriented for n, q, s, while still preserving consistent output style across episodes.
You can freely move code from the Figure 1 episodes into the shared bergner_spichtinger_2026 package if it's useful, as long as you don't break the pre-existing episodes.
Good — refactoring shared comparison utilities is allowed as long as Episodes 2–4 still pass.
Question 19: Should the backlog include a dedicated “shared infrastructure/refactor” task for Figure 2 utilities, or should that work be folded into the Python/plotting task?
My recommended answer: include a dedicated shared-infrastructure task early in the episode.
Reason:
- We’ll need reusable pieces across Python, AUTO, and LOCA: eigenvalue canonicalization, stability classification, zero-crossing detection, comparison-grid interpolation, and summary generation.
- Keeping that as its own task reduces duplication and protects existing Figure 1 workflows with regression tests.
- It also gives a natural place to add
physical_jacobian/physical_eigenvaluespackage APIs and tests before backend-specific scripts depend on them.
Agreed.
Question 20: Should we create the new episode scaffold as its own first backlog task, separate from the shared eigenvalue infrastructure?
My recommended answer: yes.
Proposed first task:
Create Episode 5 scaffold for Figure 2 eigenvalue reproduction
Scope:
- create
episodes/005-figure2-eigenvalues/README.md; - create
docs/,scripts/,outputs/,notebooks/placeholders as needed;
Show remaining 7 lines
- document the agreed scope:
p = 300 hPa,T = 230 K,F = 1,N_a = 1e10 m^-3;w = 0.0005–2.0 m s^-1;- physical ODE Jacobian eigenvalues, not log-residual eigenvalues;
- Python/AUTO/LOCA backend comparison;
- LOCA must compute physical eigenvalues backend-side using Sacado + Teuchos/LAPACK if available;
- AUTO may fall back to Python analytic eigenvalues after documenting native options.
Yes.
Question 21: What task granularity do you want for the backlog: coarse backend tasks only, or split implementation and comparison into smaller reviewable tasks?
My recommended answer: create six atomic tasks:
- Episode 5 scaffold and planning notes.
- Shared physical Jacobian/eigenvalue infrastructure:
- SymPy-derived analytic Jacobian,
- canonical eigenvalue sorting/classification,
- zero-crossing detection,
- tests.
Show remaining 19 lines
- Python Figure 2 eigenvalue reproduction:
- dense branch,
- eigenvalue CSV,
- paper-style plot draft.
- AUTO Figure 2 continuation/eigenvalue workflow:
- independent AUTO branch,
- document AUTO-native stability/eigenvalue investigation,
- fallback to Python analytic eigenvalue calculator if needed.
- LOCA Figure 2 Sacado physical Jacobian/eigenvalue workflow:
- C++ physical vector-field AD Jacobian,
- Teuchos/LAPACK eigenvalues,
- backend-side eigenvalue output.
- Integrated backend + paper comparison:
- combined plot,
- Hopf crossing summary,
- optional Figure 2 digitization,
- final metadata and README updates.
This gives clean PR-sized units and keeps the high-risk LOCA work isolated.
That looks good. Feel free to make sub-issues of any of these where it makes sense as you write them.
Created six backlog tasks:
TASK-019— Create Episode 5 scaffold for Figure 2 eigenvalue reproductionTASK-020— Add shared physical Jacobian and eigenvalue infrastructureTASK-021— Implement Python Figure 2 eigenvalue reproductionTASK-022— Implement AUTO Figure 2 continuation and eigenvalue workflowTASK-023— Implement LOCA Sacado physical Jacobian and eigenvalue workflow for Figure 2TASK-024— Produce integrated Figure 2 backend comparison and paper-facing artifacts
I encoded the decisions we reached:
Show remaining 8 lines
- paper Figure 2 range
w = 0.0005–2.0 m s^-1 - physical ODE Jacobian eigenvalues, not transformed residual eigenvalues
N_a = 1.0e10 m^-3- SymPy-derived Python analytic Jacobian
- LOCA backend-side Sacado physical Jacobian + Teuchos/LAPACK eigenvalues
- AUTO investigation with allowed Python analytic fallback
- simple Hopf zero-crossing detection only
- optional digitization as secondary evidence.
Good. Please write implementation plans for each of those issues.
Added implementation plans to:
TASK-019TASK-020TASK-021TASK-022TASK-023TASK-024